IEC 60268-1 PDF

IEC SOUND SYSTEM EQUIPMENT – PART 1: GENERAL. Buy IEC Ed. Sound system equipment. Part 1: General from SAI Global. Buy IEC SOUND SYSTEM EQUIPMENT – GENERAL from SAI Global.

Author: Zologore Mezishakar
Country: Namibia
Language: English (Spanish)
Genre: Education
Published (Last): 11 October 2005
Pages: 184
PDF File Size: 3.4 Mb
ePub File Size: 12.46 Mb
ISBN: 585-6-29462-623-5
Downloads: 47077
Price: Free* [*Free Regsitration Required]
Uploader: Akinogami

Registration required The content you have requested is available only to registered visitors. Calibrate the microphones per the instructions in the SoundCheck manual. Verfahren zur Festlegung und Messung von allgemeinen Kennwerten fuer die Geraeteleistung.

BS 6840-1:1987, IEC 60268-1:1985

You may experience issues viewing this site in Internet Explorer 9, 10 or It can be created by passing pink noise through a special filter network defined in IEC 60268-11 calibrated, position the microphones 0. This value is converted to dBV and used to calculate the IM and difference frequency stimulus levels.

Test Setup for measuring headphone voltage sensitivity. It then calculates the voltage required to produce 1 mW into the rated impedance.

Amendment 1 – Sound system equipment. Part 1: General

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. Hardware Requirements In order to run the sequences, the following hardware is required: Software Requirements SoundCheck Along with listening tests SoundExpert performs objective measurements of audio devices and technologies.

Methods for specifying and measuring general characteristics used for equipment performance Status: Learn more about the cookies we use and how to change your settings. It is generated by means of Fourier synthesis http: Connect the impedance boxes between the headphone amp out and headphone input.

  CRAFTSMAN RIDING MOWER MANUAL PDF

All signals are 30s long, kec rmsstereo, 16bit and have Hz sample rate. The Hz recorded time waveforms are processed using heterodyne analysis to 6268-1 their fundamental values.

Take the smart route to manage medical device compliance. BS EN adds an additional requirement – that the crest factor of the test signal the ratio between the instantaneous peak level of the signal and its RMS level be between 1.

First, a pink noise stimulus is played from the noise speakers and recorded by the unoccluded ears. Calibrate the Headphone Amplifier channels per the instructions in the SoundCheck manual. No – I don’t want to receive the latest audio test information by email. If the answer is No, the sequence jumps to post-processing steps which calculate passive attenuation and the final display step.

The following 35 tracks of various genres are used for objective measurements of audio equipment.

While test signals can be of any kind the measurement procedure stays the same and waveform degradation is measured with a single parameter – Difference level dB. The folder contains dependent files required to run the sequences.

IEC /AMD | IEC Webstore

A series of post-processing steps follow to apply the weighting and correction curves, calculate the LAEQ and then the Simulated Program Characteristic Voltage is calculated along with the Hz voltage sensitivity. Methods for specifying and 6268-1 general characteristics used for equipment performance. The sequence uses a stepped sine stimulus to measure frequency response, THD and impedance, a composite signal of 70 Hz and Hz with an amplitude ratio of 4: The core of the method is testing with some input signals and measuring level of their waveform degradation at the output.

  LYNN MARGULIS TEORIA ENDOSIMBIOTICA PDF

Audio equipment, Audio systems, Communication equipment, Performance testing, Acoustic testing, Acoustic measurement, Testing conditions, Accuracy, Marking, Test equipment, Experimental data, Graphic representation, Magnetic field measurement, Frequencies, Signal level, Weighting functions, Errors, Calibration.

The standard itself is a lengthy document, 9 Sections and 3 6068-1 covering 46 printed pages. T he new audio metric allows to measure waveform degradation using music as a test signal. If passive, connect to the headphone amp or separate audio power amplifier You are ready to start the sequence.

Test signals used for objective measurements – SoundExpert

There are several unique Signal Paths used in the sequences which are not a part of the default SoundCheck installation. Worldwide Standards We can source any standard from anywhere in the world. Headphones and Earphones is an international standard intended to characterize the performance of headphones and earphones.

Find Similar Items This product falls into the following categories. Band-limited version of square wave is used. In order to add these Signal Paths to your System Calibration or relink to existing Signal Paths, you should open each of the sequences individually and, if prompted, add or relink Paths to your System Calibration.

Iwc series of post processing steps calculates the attenuation curves, their average values and shows them on the final display.

Please complete the short form below all fields are required.